Model number check

ELU-199WBN

Is ELU-199WBN recalled? Yes. Model number ELU-199WBN is listed in CPSC recall 25-325: HTP residential gas boilers, announced June 5, 2025. Hazard: fire, carbon monoxide and poisoning. Remedy: repair.

Compare every letter, number, space, and suffix on your product label. A similar-looking model may not be included in a recall — the official CPSC notice is always the final authority.

Recall 25-325, published June 5, 2025

HTP residential gas boilers

What to check on the product label

Compare the model on your label, then check any serial numbers, date codes, and exclusions in the notice. A model match alone does not confirm that your unit is included.

Affected model numbers

ELU-199WBN
Additional identifying details

The serial number, model number and product name are located on the rating plate on the left-hand side of the boiler.

Which products are included?

This recall involves HTP-brand ELU Elite Ultra residential wall-mounted gas boilers with model numbers ELU-150WBN and ELU-199WBN. The boilers are black in color and measure about 20 inches wide and 34 inches high. The serial number, model number and product name are located on the rating plate on the left-hand side of the boiler. Model Name/ Number Serial Number(s) or Range ELU Elite Ultra / ELU-150WBN 3260035C8 (242770000111-242850000104) ELU Elite Ultra / ELU-199WBN 3260036C8 (243240000051-250150000084)

Confirm these details on the official CPSC notice

Why it was recalled

The boiler door can fail to seal properly, due to incorrect burner door studs, allowing flames and gases to escape, posing fire and carbon monoxide (CO) poisoning hazards that can result in death or serious injury.

Official remedy

Consumers should immediately stop using the recalled boilers and contact HTP to arrange to have a certified technician install the repair at no cost to the consumer. Consumers who must continue using the boiler while awaiting repair should have working smoke and carbon monoxide alarms in their homes.

Remedy type: Repair

Brand
HTP residential gas
Recall published
June 5, 2025
Units
About 96 (In addition, 9 were sold in Canada)
Sold at / sales period
Independent heating and plumbing contractors and wholesale distributors nationwide from October 2024 through February 2025 for between $3,400 and $4,100.