Model number check

37C57U

Is 37C57U recalled? Yes. Model number 37C57U is listed in CPSC recall 04-128: LP and Convertible Gas Water Heater Temperature Controls, announced April 28, 2004. Hazard: fire.

Compare every letter, number, space, and suffix on your product label. A similar-looking model may not be included in a recall — the official CPSC notice is always the final authority.

Recall 04-128, published April 28, 2004

LP and Convertible Gas Water Heater Temperature Controls

What to check on the product label

Compare the model on your label, then check any serial numbers, date codes, and exclusions in the notice. A model match alone does not confirm that your unit is included.

Affected model numbers

37C57U
Additional identifying details

A white label with red lettering located on the right side of the control contains one of the following model numbers: 37C55U 658, 37C57U 602, 37C72U 520, 37C72U 546, 37C72U 547, or 37C72U 548, and 37C72U 676.

Which products are included?

The temperature control is a small metal box located above the access panel door of the gas water heater. A white label with red lettering located on the right side of the control contains one of the following model numbers: 37C55U 658, 37C57U 602, 37C72U 520, 37C72U 546, 37C72U 547, or 37C72U 548, and 37C72U 676. There should be a four- digit metal stamped date code located below the label on the right side of the control. Recalled controls will have date codes 0240 to 0329 (40th week of 2002 to 29th week of 2003). Potentially affected gas water heaters include: AO Smith, Apollo, Crosley, Energysense, Freedom, Intertherm, Kenmore, Maytag, Mission, Myers, Penfield, President, Reliance, Sentry, or State. Beginning serial numbers on these gas water heaters can be checked at www.regcen.com/tempcontrolrecall

Confirm these details on the official CPSC notice

Why it was recalled

The gas water heater controls can gradually open instead of snapping open to full flow, which can cause soot to build up on the water heater burner, presenting a fire hazard.

Official remedy

Contact White-Rodgers to arrange for a qualified service technician to replace the recalled control, free of charge.

Brand
LP and Convertible Gas
Recall published
April 28, 2004
Units
88,000
Sold at / sales period
Retail distributors and independent servicers have sold and/or installed water heaters with the controls, from October 2002 through March 2004.

Other model numbers in this recall

Related recalls