RecalledRecall 07-120Published

One World Technologies Ryobi Router Table Throat Plates

One World Technologies Recalls Throat Plates Sold with Ryobi Router Tables Due to Laceration Hazard

Units
About 100,000 units
Incidents
3 reports
Remedy
See the notice

CPSC recall 07-120, announced March 6, 2007, covers One World Technologies Ryobi Router Table Throat Plates (about 100,000 units). The throat plates do not securely snap into the router's table top bit opening. The notice cites 3 incident reports. Consumers should immediately check their router tables to ensure that the throat plates securely snap into the router bit opening. Recall contact: call (800) 525-2579, or go to www.ryobitools.com.

What to check on the product label

Compare the model on your label, then check any serial numbers, date codes, and exclusions in the notice. A model match alone does not confirm that your unit is included.

Affected model numbers

Additional identifying details

The recall involves Ryobi-brand router tables, with model number RT101, which is written on the table's data plate, located on its front leg.

Which products are included?

The recall involves Ryobi-brand router tables, with model number RT101, which is written on the table's data plate, located on its front leg. These tables were sold as part of the Ryobi combo kits with model numbers R161RTA and R162RTA. The combo kit model number is written on the packaging. A router table holds the router underneath the table. Instead of moving the router over the wood, the table allows the user to guide the wood for cutting. The throat plates are components of the table that consist of five yellow plastic rings. They serve as a guide for the router bit and provide a stable surface around the bit.

Confirm these details on the official CPSC notice

Why it was recalled

The throat plates do not securely snap into the router's table top bit opening. The throat plate can come loose during operation and be ejected from the table top, posing a laceration hazard to consumers.

Incidents and injuries

One World Technologies has received three reports of throat plates coming loose during use. Two consumers were struck on the nose by the throat plate and received a minor cut and bruising.

Official remedy

Consumers should immediately check their router tables to ensure that the throat plates securely snap into the router bit opening. If any throat plates do not securely snap into the table top, consumers should stop using the router table immediately and contact One Word Technologies for a free replacement set of throat plates.

Product and sales details

Manufacturer
One World Technologies Inc., of Anderson, S.C.
Product type
Tables
Recall number
07-120
Units
About 100,000
Manufactured in
China
Sold at / sales period
Home Depot stores nationwide between May 2004 and January 2007 for about $100 for the combo kits that include the router, router table and throat plates.

Ryobi Router Table Throat Plates

CPSC product type: Routers & Accessories

Recall contact information

For more information, consumers can call One World Technologies Inc. at (800) 525-2579 between 8 a.m. and 5 p.m. ET Monday through Friday, or go to the firm's Web site at www.ryobitools.com

Verify phone numbers, hours, and websites on the current CPSC notice before contacting the firm.

Know someone who has one?

Recalls only work when owners hear about them. Send this notice to family or friends who might own the same product.

Related recalls

Other notices from the same brand or product category.