Model number check

KS-6000

This model number appears in one official CPSC recall notice for household products. Latest recall published November 13, 2006.

Compare every letter, number, space, and suffix on your product label. A similar-looking model may not be included in a recall — the official CPSC notice is always the final authority.

Recall #07-507 · Published November 13, 2006

Ansul K-GUARD®, SENTRY® and FLAG FIRE® Model Fire Extinguishers

What to check on the product label

Compare the model on your label, then check any serial numbers, date codes, and exclusions in the notice. A model match alone does not confirm that your unit is included.

Affected model numbers

KS-6000
Additional identifying details

Check the product label for these CPSC-listed model numbers: K01-1, K01-2, W02-1, KS-6000, PWS-25G.

Which products are included?

The recall involves K-GUARD® Wet Chemical, FLAG FIRE® KITCHEN ONE® Wet Chemical, FLAG FIRE® Water and SENTRY® Water Fire Extinguishers manufactured and shipped between May 2003 and September 9, 2005. The recall program involves pick-up tube replacements in the following extinguishers: Brand Model Part Number(s) K-GUARD® Wet Chemical K01-1 430849 (UL) 430850 (ULC) K01-2 432843 (UL) 432848 (ULC) SENTRY® Water W02-1 430847 (English) 430848 (Spanish/English) FLAG FIRE® KITCHEN ONE® Wet Chemical KS-6000 552055 (UL) 552500 (ULC) FLAG FIRE® Water PWS-25G 552050 (UL) 552501 (ULC) Model numbers can be found on the fire extinguisher labels. Affected models meet the following criteria: The year 2004 or 2005 is stamped on the hanger hook attachment on the shell. For 2003 models, information on specific serial numbers included in the recall can be found at www.ansul.com for the K-GUARD Wet Chemical and SENTRY Water extinguishers, or at www.pyrochem.com for the FLAG FIRE and KITCHEN ONE Wet Chemical extinguishers. Contact the firm to determine if your extinguisher is included in this replacement program.

Confirm these details on the official CPSC notice

Why it was recalled

If the fire extinguisher is dropped horizontally from a height of approximately 2 to 3 feet, the pick-up tube could crack at the threads between the pick-up tube adaptor and the stainless steel tube. If a pick-up tube is cracked, the extinguisher can fail to discharge properly when activated, which can put users at risk during a fire.

Official remedy

Pick-up tube replacements will be performed during routine annual maintenance. The pick-up tube assembly is inside the extinguisher and cannot be visually inspected without de-pressurizing and disassembling the extinguisher. This work should only be done by an authorized ANSUL® distributor. Owners concerned about an extinguisher prior to the scheduled maintenance, due to signs of physical damage such as dents or scratches, should contact their authorized ANSUL® distributor to request a free replacement.

Brand
Ansul
Recall published
November 13, 2006
Units
About 154,000
Sold at / sales period
Ansul Incorporated, through its authorized fire equipment distributors, from May 2003 through September 2005. Extinguishers were sold by distributors to their end users for about $150 to $225 each for the kitchen units and for about $100 each for the water units.

Other model numbers in this recall

Related recalls

Selected by shared brand or household-product category.

No. 06-151Smoke & CO Alarms

First Alert® Smoke Alarms and Combination Smoke/CO Alarms Recalled for Rapidly Draining Battery Power

BRK Brands

Hazard: These alarms can drain the power from batteries rapidly, causing premature low battery power. Consumers will be alerted to the low battery power and the need to replace the battery by a chirping of the unit. If the batteries on the smoke/CO alarm are not replaced before the battery power terminates, the alarm will not detect smoke in the event of a possible fire and the presence of carbon monoxide.