Is DGAM075BDF recalled? Yes. Model number DGAM075BDF is listed in 2 CPSC recalls: 12-102 (Coleman, Coleman Evcon and Red T Gas Furnaces for Manufactured Homes, February 3, 2012) and 05-047 (Gas Furnaces, November 15, 2004).
Compare every letter, number, space, and suffix on your product label. A similar-looking model may not be included in a recall — the official CPSC notice is always the final authority.
Compare the model on your label, then check any serial numbers, date codes, and exclusions in the notice. A model match alone does not confirm that your unit is included.
Affected model numbers
DGAM075BDF
Additional identifying details
The model number is written on a faceplate, found by removing both front access panels.
Which products are included?
The recall involves Coleman, Coleman Evcon and Red T brand furnaces. The furnaces are silver with white access panels. "Coleman," "Coleman Evcon" and "Red T" brand names are located on the middle of the front access panel. The model number is written on a faceplate, found by removing both front access panels. The faceplate is found mounted on the left inside surface behind the lower panel. Models included in the recall are: DGAM075BDD DGAM075BDE DGAM075BDF DGAT070BDD DGAT070BDE DGAT070BDF DGAT075BDD DGAT075BDE DGAT075BDF DLAS075BDD DLAS075BDE DLAS075BDF
The furnace can overheat and cause the heat-exchanger to crack and create openings that allow flames to be exposed. When this happens, drywall and other nearby combustibles are exposed to the flames, posing a fire and smoke hazard to consumers.
Official remedy
Consumers should immediately stop using the furnace until it has been inspected and repaired. Consumers should contact UPG to schedule a free inspection and repair of any furnace involved in the recall.
Remedy type: Repair
What should I do if I have DGAM075BDF?
Confirm the model number. Find the label and compare every letter and digit with DGAM075BDF.
Stop using it. The notice says to stop using recalled units immediately.
Compare the model on your label, then check any serial numbers, date codes, and exclusions in the notice. A model match alone does not confirm that your unit is included.
Affected model numbers
DGAM075BDF
Additional identifying details
These model furnaces with model numbers listed below are included in the recall: DGAM075BDD DGAM075BDE DGAM075BDF DGAT070BDD DGAT070BDE DGAT070BDF DGAT075BDD DGAT075BDE DGAT075BDF DLAS075BDD DLAS075BDE DLAS075BDF The model number is written on a nameplate, found by removing both front access panels.
Which products are included?
The recall involves Coleman, Coleman Evcon and Red T brand furnaces. The furnaces are a silver color with white access panels. The "Coleman," "Coleman Evcon" and "Red T" brand names are located on the middle of the front access panel. These model furnaces with model numbers listed below are included in the recall: DGAM075BDD DGAM075BDE DGAM075BDF DGAT070BDD DGAT070BDE DGAT070BDF DGAT075BDD DGAT075BDE DGAT075BDF DLAS075BDD DLAS075BDE DLAS075BDF The model number is written on a nameplate, found by removing both front access panels. The nameplate is found mounted on the left inside surface behind the lower panel.
These furnaces can overheat, causing heat-exchanger cracking, burn-through and, in extreme cases, furnace wrapper burn-through. This can lead to heating and possible burning of the drywall and other combustibles adjacent to the furnace, which poses a fire and smoke hazard to consumers.
Official remedy
Consumers should not use the heating function of these furnaces until it has been inspected and repaired. Consumers should contact UPG to schedule a free inspection and repair of any furnace involved in the recall.
Brand
The Unitary Products Group (UPG) of York International
These furnaces were sold nationwide between 1995 and 2000 under the brand names of Coleman, Coleman Evcon and Red T as original equipment in manufactured homes and as replacement furnaces in manufactured homes.