Model number check

2000AC

This model number appears in 2 official CPSC recall notices for household products. Latest recall published November 6, 1978.

Compare every letter, number, space, and suffix on your product label. A similar-looking model may not be included in a recall — the official CPSC notice is always the final authority.

Recall #78-089 · Published November 6, 1978

AMF AC-powered smoke detectors

What to check on the product label

Compare the model on your label, then check any serial numbers, date codes, and exclusions in the notice. A model match alone does not confirm that your unit is included.

Affected model numbers

2000AC
Additional identifying details

They have the following model numbers: BRK SS749AC (hard wire) SS749ACS (hard wire) SS749L (line cord) SS749SL (line cord) AMF 2000AC (hard wire) 2000ACL (line cord) I-T-E ITOl-AC (hard wire) Sears 9-57049 (hard wire) 9-57047 (line cord) 9-57048 (line cord) Homeowners who suspect they have one of these smoke detectors are urged to check the model number on their unit. (Caution: Before inspecting-hard-wired detectors, electrical power to the unit must be turned off at the fuse box or circuit breaker; line cord detectors must be unplugged before inspection).

Which products are included?

Read the full CPSC product description and restrictions

Smoke Detectors Recalled by BRK Electronics NEWS from CPSC U.S. Consumer Product Safety Commission Office of Information and Public Affairs Washington, DC 20207 FOR IMMEDIATE RELEASE November 6, 1978 Release # 78-089 Pittway-BRK Press Release WASHINGTON, D.C. (Nov. 6) - The Consumer Product Safety Commission (CPSC) today announced an agreement with the Pittway Corp., Northbrook, Ill., doing business as BRK Electronics, whereby Pittway has agreed to pay $100,000 in settlement of a civil penalty action which the Commission had decided to file. The agreement was negotiated between Pittway and CPSC staff and accepted by the Commission on Nov. 1. The Commission's action against Pittway concerned the company's alleged failure to report a defect in the BRK SS749 series smoke detectors which could cause such products to fail to operate and, in certain instances, to catch fire. The defect consisted of incorrectly rated resistors used in the SS749 smoke detectors produced by the BRK Electronics division of Pittway from March 1974 to September 26,1975. The Consumer Product Safety Act requires a manufacturer to notify the Commission immediately after learning of a defect which could create a substantial product hazard. In agreeing to a settlement of this matter, the Pittway Corporation has neither admitted nor denied violating the notification requirements of the Act. The company has cooperated in voluntarily carrying out an extensive program to recall the approximately 115,000 smoke detectors involved. Thus far, approximately 60,000 smoke detectors have been returned. The company has agreed to continue, and to intensify, its efforts to locate the remaining smoke detectors. The units subject to this recall are 110 volt AC-powered detectors which sold for a suggested retail price of $39.95. No battery-powered detectors are involved. Some models were manufactured with ordinary power cords (line cord) which plug into wall outlets, others have pigtail leads (hard wire) for installation directly into electric wiring. The detectors were marketed by BRK, American Machine & Foundry (AMF), I-T-E Imperial Corporation (I-T-E) and Sears, Roebuck & Company (Sears). They have the following model numbers: BRK SS749AC (hard wire) SS749ACS (hard wire) SS749L (line cord) SS749SL (line cord) AMF 2000AC (hard wire) 2000ACL (line cord) I-T-E ITOl-AC (hard wire) Sears 9-57049 (hard wire) 9-57047 (line cord) 9-57048 (line cord) Homeowners who suspect they have one of these smoke detectors are urged to check the model number on their unit. (Caution: Before inspecting-hard-wired detectors, electrical power to the unit must be turned off at the fuse box or circuit breaker; line cord detectors must be unplugged before inspection). Once the power is off o remove the cover and examine the side of the plastic base for a label which contains the model number. Anyone who has one of the Sears units affected by this recall should contact the nearest Sears store, which will arrange for inspection and free replacement of the unit containing the defect. People who believe they have any of the other detectors under recall should contact BRK to obtain a fact sheet, which gives very specific criteria for identifying potentially defective units, as well as replacement instructions. Additional information concerning the recall can be obtained by contacting BRK Electronics, 780 McClure Avenue, Aurora, Illinois 60507, Attention: Dennis Wm. Clair, Project 749 Director; or by calling toll-free 800/323-9005 and asking for the Project 749 Department.

Confirm these details on the official CPSC notice

Why it was recalled

The API record does not contain a separate hazard field. Read the official notice for complete details.

Official remedy

No separate remedy text is present in the API record. Follow the official CPSC notice.

Brand
AMF
Recall published
November 6, 1978

Other model numbers in this recall

Recall #77-083 · Published August 1, 1977

BRK AC-powered smoke detectors

What to check on the product label

Compare the model on your label, then check any serial numbers, date codes, and exclusions in the notice. A model match alone does not confirm that your unit is included.

Affected model numbers

2000AC
Additional identifying details

They have the following model numbers: BRK SS749AC (hard wire) SS749ACS (hard wire) SS749L (line cord) SS749SL (line cord) AMF 2000AC (hard wire) 2000ACL (line cord) I-T-E IT0l-AC (hard wire) Sears 9-57049 (hard wire) 9-57047 (line cord) 9-57048 (line cord) Homeowners who suspect they have one of these smoke detectors are urged to check the model number on their unit. (Caution: Before inspecting hard-wired detectors, electrical power to the unit must be turned off at the fuse box or circuit breaker; line cord detectors must be unplugged before inspection).

Which products are included?

Read the full CPSC product description and restrictions

Smoke Detectors Recalled by BRK Electronics NEWS from CPSC U.S. Consumer Product Safety Commission Office of Information and Public Affairs Washington, DC 20207 FOR IMMEDIATE RELEASE August 1, 1977 Release # 77-083 Recall Of Smoke Detectors Continues WASHINGTON, D.C. (Aug. 1) -- BRK Electronics, in cooperation with the U.S. Consumer Product Safety Commission (CPSC), today issued a second notice of the recall of all BRK SS749 series smoke detectors manufactured before September 26, 1975. The first notice of this recall was issued January 25, 1977, but between 85-90,000 of these smoke detectors have not been located. The recall was begun voluntarily by BRK when the company discovered that incorrectly- rated resistors were used in the SS749 series smoke detectors produced from March 1974 to September 26, 1975. These resistors could fail, making the unit inoperable, and may under certain circumstances cause a fire inside the detector. Although the detector is enclosed in self-extinguishing plastic, the units are being recalled as a precautionary measure. According to BRK, all distributors who purchased the detectors have been contacted and with the company's help have been notifying the contractors who installed the detectors to organize factory supervised replacement programs. The units subject to this recall are 110 volt AC-powered detectors which sold for a suggested retail price of $39.95. No battery-powered detectors are involved. Some models were manufactured with ordinary power cords (line cord) which plug into wall outlets, others have pigtail leads (hard wire) for installation directly into the household circuit The units subject to this recall are 110 volt AC-powered detectors which sold for a suggested retail price of $39.95. No battery-powered detectors are involved. Some models were manufactured with ordinary power cords (line cord) which plug into wall outlets, others have pigtail leads (hard wire) for installation directly into electric wiring. The detectors were marketed by BRK, American Machine & Foundry (AMF), I-T-E Imperial Corporation (I-T-E) and Sears, Roebuck & Company (Sears). They have the following model numbers: BRK SS749AC (hard wire) SS749ACS (hard wire) SS749L (line cord) SS749SL (line cord) AMF 2000AC (hard wire) 2000ACL (line cord) I-T-E IT0l-AC (hard wire) Sears 9-57049 (hard wire) 9-57047 (line cord) 9-57048 (line cord) Homeowners who suspect they have one of these smoke detectors are urged to check the model number on their unit. (Caution: Before inspecting hard-wired detectors, electrical power to the unit must be turned off at the fuse box or circuit breaker; line cord detectors must be unplugged before inspection). Once the power is off, remove the cover and examine the side of the plastic base for a label which contains the model number. Anyone who has one of the Sears units affected by this recall should contact the nearest Sears store, which will arrange for inspection and free replacement of the unit containing the defect. People who believe they have any of the other detectors under recall should contact BRK to obtain a fact sheet, which gives very specific criteria for identifying potentially defective units, as well as replacement instructions. Additional information concerning the recall can be obtained by contacting BRK Electronics, 780 McClure Avenue, Aurora, Illinois 60507, Attention: Dennis Wm. Clair, Project 749 Director; or by calling toll-free 800/323-9005 and asking for the Project 749 Department.

Confirm these details on the official CPSC notice

Why it was recalled

Fire & Fire-Related Burn

Official remedy

No separate remedy text is present in the API record. Follow the official CPSC notice.

Brand
BRK
Recall published
August 1, 1977

Other model numbers in this recall

Related recalls

Selected by shared brand or household-product category.